Re-hardening water filter HANSUN FIL-1.5 trouble shooting

Problem

Cause

Action

Low capacity

Solids and foreign particles
clogging inside

Back washing completely

Distributor broken and sand clogging inside

Change distributor

Low pressure of inlet pressure and capacity

Check inlet water source and keep it in good order

Bad smell and taste

Filter material over-time
working

Change filter material

Bad water source

Check the quality of
source fresh water

 

Mineralizer DONG KWANG DKM-10 trouble shooting

Problem

Cause

Action

No pressure in the vessel

Inlet valve and line is closed

Check inlet valve

 

Upper 3- way valve is closed

Check upper 3-way valve

Leakage from cleaning hole

Hole nuts is not tighten

Tighten nuts

Ph value of the water is not correct

Level of filter material is too low

If value is below 6.5, add dolomite

Pressure drop is too high

Inner filter's surface is polluted

Back flushing at least for 20 min

Last modified: Monday, 13 March 2023, 11:47 AM