Procedure for operation of the overboard water cooling system
a) Make sure the overboard water main is filled with
water as described above. Depending on the location of the boat (deep or
shallow water), use a bottom or side kingboard to pump overboard water.
b) Make sure all valves on the pressure gauges and
devices are open.
Evaluate
the temperature of the overboard water and decide how much central coolers to
use.
c)
Start one main cooling
overboard water pump from the local control panel with the drain valve closed.
Then slowly open the drain valve.
d)
Open the valves of the
other main cooling pumps behind the on-board water.
e)
Bleed the central
coolers to ensure full overboard water flow through each cooler
f) Switch off the running overboard water pump on the ECR remote
control. Then set all three pumps to AUTO CHANGE mode. And restart the pump
that was running before. If one pump is not enough, switch on two pumps.
g) Turn
on the marine growth prevention system used in the Kingston filter. It is very
important that the MGPS is used only in that filter and only when water flows
through it.