When the scrubber is in "Open Cycle" mode, the overflow water is directed past the cooler to the scrubber. The supply pumps supply the required amount of on-board water to the nozzles in the reactor and absorber sections. The valves connecting the scrubber wash water outlet to the water outlet overboard are open. SW/FW operating mode changeover valves are switched so that the wash water supply pump pumps only on-board water.
The level control valve maintains a certain amount of water in the Residence Tank. This allows the wash water to be degassed before it is released overboard. The analysis unit monitors the pH, turbidity, and PAH of the effluent.
In order to reduce the turbidity and PAH contamination of the effluent wash water, the water in the Discharge Tank is treated in a dedicated treatment plant (Hydro cyclone). The sludge isolated during the treatment process is collected and stored in an on-board sludge tank.

Exhaust gas cleaning system operation in Open Cycle Seawater (SW) mode