Procedure to Stop the Separator
a) First you need to press the Process START/ STOP button. The
two parts of the program will then be activated (fuel ejection / storage and
bowl emptying) and the separator will stop automatically. The HFO will be
automatically recirculated through the three-way valve back to the HFO settling
tank.
b) It is necessary to adjust the steam supplied to the heater to allow
the fuel to cool.
c) The supply pump must be stopped if it is in manual mode.
d) Close the separator control air and water valves along with all
other valves opened before starting.
e) When the separator comes to a complete stop, the brake can be
applied and prepared for cleaning if necessary.
The above description of the fuel cleaning
process was related to the operation of the FO separator No. 1. If a No.2 FO
separator is required, the piping diagrams and valve positions should be
carefully considered before beginning any operations.
NOTE: Strict
separation and disassembly of the separator manufacturer's instructions must be
followed to avoid damage. The separator bowl rotates at very high speeds, and
any imbalance or loose connection can have serious consequences.