The exhaust gas cleaning system stops
uncontrollably when the EMERGENCY STOP button is pressed or the main power
switch (MAIN SWITCH) to the OFF position is toggled without first stopping the
scrubber, or when the power supply is interrupted. This is the case with such
an uncontrolled stop:
- The scrubber bypass
valve opens and releases the exhaust directly into the atmosphere.
- The scrubber suction
valve will remain in the position in which it is located. If it is in the open
position, the exhaust backflow will enter the scrubber. If this happens when
one or more engines are running, the temperature in the scrubber would rise
rapidly and could seriously damage it.
- All the main outputs of
the flue gas cleaning system are switched off. This means that software
commands will not be executed for these outputs.