Scrubber Bypass Modes
Engine exhaust is routed to the side of the
scrubber if it is not operating properly or is turned off. The scrubber bypass
valve opens if:
- Press the bottom - SCRUBBER STOP.
- Press the bottom - EMERGENCY STOP.
- There is a fault in the pneumatic or electrical supply to the bypass valve.
- An alarm has been triggered at the exhaust intake or other module or unit that stops the entire scrubber.
NOTE: The bypass damper control can be disconnected manually. The suction valve leading to the scrubber operates separately.