Command and control elements
Diesel Generator
Figure 69. Diesel Generator Panel
1 – Ampmeter, 2 – Voltmeter, 3 – Frequency meter, 4 – Kilowattmeter, 5 – Current Line Changeover switch (0 – L1 – L2 – L3), 6 – Voltage Phase Changeover switch (0 – L1L2 – L2L3 – L3L1), 7 – Mode (Manual – Remote), 8 – Heating Control (On – Off), 9 – Heating indication (blue), 10 – Generator Breaker, 11 – Generator Breaker indication (red), 12 – Generator Breaker indication (green).
Shaft Generator
Figure 70. Diesel Generator Panel
1 – Ampmeter, 2 – Voltmeter, 3 – Frequency meter, 4 – Kilowattmeter, 5 – Current Line Changeover switch (0 – L1 – L2 – L3), 6 – Voltage Phase Changeover switch (0 – L1L2 – L2L3 – L3L1), 7 – Mode (Manual – Remote), 8 – Heating Control (On – Off), 9 – Heating indication (blue), 10 – Shaft Generator Breaker, 11 – Shaft Generator Breaker indication (red), 12 – Shaft Generator Breaker indication (green).
Synchronization panel
Figure 71. Synchronization Panel
1 – STBD Busbar Insulation Resistance control, 2 – Ampmeter, 3 – Busbar STBD Voltmeter, 4 – Busbar PS Voltmeter, 5 – PS Busbar Insulation Resistance control, 6 – Current Line Changeover switch (0 – L1 – L2 – L3), 7 – STBD Busbar Voltage Phase Changeover switch (0 – L1L2 – L2L3 – L3L1), 8 – PS Busbar Voltage Phase Changeover switch (0 – L1L2 – L2L3 – L3L1), 9 – Frequency meter, 10 – Synchronoscope, 11 – Synchronization Selector switch, 12 – Bustie Breaker, 13 – Shore Connection Breaker Pushbutton OPEN (red), 14 – Diesel Generator 1 Breaker Pushbutton OPEN (red), 15 – Shaft Generator 1 Breaker Pushbutton OPEN (red), 16 – Bustie Breaker Pushbutton OPEN (red), 17 – Shaft Generator 2 Breaker Pushbutton OPEN (red), 18 – Diesel Generator 2 Breaker Pushbutton OPEN (red), 19 – Shore Connection Breaker Pushbutton CLOSE (green), 20 – Diesel Generator 1 Breaker Pushbutton CLOSE (green), 21 – Shaft Generator 1 Breaker Pushbutton CLOSE (green), 22 – Bustie Breaker Pushbutton CLOSE (green), 23 – Shaft Generator 2 Breaker Pushbutton CLOSE (green), 24 – Diesel Generator 2 Breaker Pushbutton CLOSE (green), 25 – Diesel Generator 1 Speed control (Decrease – OFF – Increase), 26 – Bustie Breaker Mode (Manual – Remote), 27 – Diesel Generator 2 Speed control (Decrease – OFF – Increase).
Figure 72. Steering Gear Control
1 – Operational indication (green), 2 – Heating indication (blue), 3 – Power Supply indication (grey), 4 – PS Steering Gear Emergency Operation (red), 5 – STBD Steering Gear Emergency Operation (blue), 6 – Selector switch control (Remote control – Stop – Local control).